You can determine your electrical service by locating the main breaker in your service panel and reading its amperage rating, then confirming that rating against the size of the service entrance conductors and the details on the meter and panel labels. Many Texas homes use 150 amp or 200 amp service, but your exact size depends on the original installation, the home age, and any upgrades. Homeowners often consult an electrician for this process, since service size affects safety, appliance choices, and the ability to add items like an electric vehicle charger or a new heat pump. Understanding your service with the help of an electrician helps you plan projects confidently while avoiding nuisance trips and overheated equipment.

Understanding What Electrical Service Means
Definition of Electrical Service
Your electrical service is the total capacity that the utility supplies to your home through the meter and into the main service panel. It is measured in amperes and represents how much current your home can safely draw at one time. The service includes the utility conductors, meter, service disconnect, and the main panel that distributes power to branch circuits.
Why Knowing Your Electrical Service Matters
Service size determines what your home can support without overloads. If you are planning a kitchen renovation in Dallas Fort Worth, installing a spa in the backyard, or adding a level two electric vehicle charger, your service rating informs what is possible without upgrades. It also helps diagnose issues such as frequent breaker trips or lights that dim when the air conditioner starts.
Common Electrical Service Sizes in Homes 100A, 150A, 200A, etc.
Older Texas homes often have 100 amp service. Many homes from the last few decades were built with 150 amp or 200 amp service. Larger custom homes or properties with substantial loads may have 320 amp or 400 amp service. The service that is right for you depends on current load and any future plans.
Key Components of an Electrical Service
Service Drop or Lateral
The service drop is the overhead connection from the utility pole to your home. The service lateral is the underground equivalent. Both deliver power to your meter base. In North Texas neighborhoods you will find both styles depending on subdivision design and age.
Electrical Meter and Its Purpose
The meter measures energy usage for billing and also signals the type of service. Some meter bases include labeling that indicates the maximum continuous rating and the class of socket. While the meter does not set the service size on its own, its nameplate can help confirm the overall system rating.
Main Service Panel Breaker Box
The main service panel houses the main disconnect breaker and the branch circuit breakers. The rating on the main disconnect is often the most direct indicator of service size. Labels inside the panel cover also list the enclosure rating and acceptable main breaker sizes.
Service Entrance Cable
These conductors run from the meter to the main panel. The conductor gauge and insulation type must match or exceed the service rating. Copper and aluminum have different ampacities, so it is important to identify the material correctly when verifying capacity.
Step by Step Guide to Determine Your Electrical Service Size
Step 1 Locate Your Main Service Panel
Find the panel location. In Texas homes it is often in the garage, a utility room, or on an exterior wall. Ensure hands are dry and you have good lighting. Do not touch bare metal parts. Open the door to view labels and breaker handles.
Step 2 Identify the Main Breaker Rating
At the top or bottom of the panel there is a large two pole breaker labeled Main. Look for a number stamped or printed on the handle such as 100, 150, or 200. That number is the amperage. In many cases the main breaker value equals the service size.
Step 3 Check Wire Gauge and Type
With the panel door open but the dead front still in place, you can sometimes read conductor markings near the panel throat or along exposed sections of the service entrance cable. You might see text like AWG size and conductor material. Aluminum conductors are common for service feeders. Conductor ampacity must support the main rating. If you cannot read markings safely, stop and have a licensed electrician confirm.
Step 4 Look for Manufacturer Labels or Markings
Inside the panel door there should be a factory label that lists the panel model, maximum main breaker size, and the number of spaces. You can compare the main breaker rating to the panel maximum to make sure they match. The meter base may also have a sticker with a socket rating that supports your findings.
Step 5 Calculate Total Load Optional for Accuracy
If your home has many large appliances, a load calculation refines the answer. This method totals general lighting and receptacle load based on square footage, then adds fixed appliances such as ranges, dryers, air conditioning equipment, water heaters, and an electric vehicle charger. Diversity factors reduce the total to reflect that not everything runs at once. A proper calculation confirms whether the installed service is adequate.
Example of Load Calculation for a Typical Home
Consider a three bedroom home in North Texas with two thousand two hundred square feet, central air conditioning, electric range, and an electric vehicle charger. General lighting load is calculated based on floor area. Fixed appliances are added with appropriate demand factors. After applying diversity and the largest motor adjustment, the final result may show that a 200 amp service provides safe headroom for seasonal peaks. The exact math depends on the actual nameplate ratings of your equipment.
When to Consult a Licensed Electrician
Call a licensed electrician if the panel labeling is missing, the conductors are difficult to identify, or you suspect modifications over the years. Professional testing tools and field experience can validate sizing without guesswork. This is especially important before investing in an electric vehicle charger or a high efficiency heat pump system that will run during summer afternoons when the Texas grid is under heavy demand.
| Service Size | Typical Home Profile in Texas |
|---|---|
| 100 amp | Older small homes with limited electric appliances and gas heat |
| 125 amp | Modest updates with a few added loads and no large additions |
| 150 amp | Mid sized homes with electric range or larger HVAC |
| 200 amp | Modern homes with multiple high draw appliances or plans for an EV |
| 320 to 400 amp | Large homes, workshops, or properties with dual systems and heavy loads |
- Service size affects what you can add without nuisance breaker trips.
- Panel and meter labeling provide reliable clues to capacity.
- Conductor gauge must align with the main rating to be compliant.
- Load calculations confirm real world suitability for your equipment.
- Professional verification prevents unsafe assumptions during renovations.
Signs You May Need to Upgrade Your Electrical Service
Frequent Breaker Trips or Flickering Lights
If lights dim when the air conditioner starts or the breaker trips when the microwave and toaster run together, the system may be close to its limit. These symptoms can also indicate loose connections, so a thorough inspection is important.
Adding High Demand Appliances or EV Chargers
Level two charging, a new electric range, or a pool heat pump adds significant continuous load. An evaluation ensures the service can carry these additions on summer peaks when everything tends to run at once.
Home Renovations or Expansions
Kitchen and bathroom remodels, room additions, or converting a garage to conditioned space often push older services beyond safe margins. Planning an upgrade during renovations prevents rework later.
Old Fuse Boxes or Outdated Wiring
Fuse panels or very old breaker panels may not meet modern safety expectations. Aging equipment, corrosion, and limited space for new circuits are all cues that a service upgrade should be considered.
Professional Inspection and Safety Tips
Why DIY Electrical Assessments Can Be Risky
Service equipment contains energized parts even when branch breakers are off. A mistaken probe with a screwdriver or meter can cause injury. Reading the wrong label can also lead to incorrect conclusions and unsafe load decisions.
How Electricians Measure Service Capacity Safely
Electricians use clamp meters, infrared imaging, and experience with conductor sizing to verify ratings without exposing you to live gear. They review panel and meter labels, confirm conductor sizes, and evaluate heat signatures during typical household loads.
Scheduling a Professional Electrical Audit
A professional audit documents the current service size, panel condition, available breaker spaces, grounding and bonding integrity, and any signs of thermal stress. It also includes a load assessment to model seasonal peaks typical of North Texas summers.
Frequently Asked Questions
What is the difference between amps and volts
Volts represent electrical pressure. Amps represent current flow. Your service size is an amp rating that indicates how much current your home can safely draw at the supplied voltage. Most Texas homes receive split phase service that provides 120 volts to standard outlets and 240 volts to larger appliances.
Can I upgrade from 100A to 200A service myself
An upgrade requires permits, utility coordination, correct conductor sizing, grounding and bonding verification, and inspection. For safety and compliance, this work should be performed by a licensed electrician who understands local utility requirements and inspection standards.
How long does an electrical service upgrade take
Time lines vary based on permitting, utility scheduling, and site conditions. The physical changeover on the day of work is usually completed within a single workday, but planning and coordination occur before that. Your electrician will guide you through the steps so power downtime is minimized.

Final Thoughts
Importance of Knowing Your Service Capacity for Safety and Efficiency
Knowing your electrical service size helps you avoid overloads, plan upgrades, and keep your family safe. It is the foundation for smart decisions about appliances, comfort systems, and vehicle charging.
When to Contact a Licensed Electrician
If labeling is unclear or you plan to add significant load, consult a licensed electrician for a documented assessment. A clear picture of your current capacity prevents costly surprises during projects.
Conclusion
To summarize, you determine your electrical service by reading the main breaker rating, confirming conductor size and panel labeling, and using load calculations to validate real world needs. This knowledge answers the original question and equips you to make safe choices about renovations and new equipment. When you want an experienced team to evaluate and plan with you, reach out to Matrix Electric Company Inc. You can also explore more by visiting the company website at matrixelectric dot net.